LESSON 12 · INTERMEDIATE · SHORT LESSON
Flow Control Valves
Controls actuator speed by regulating the flow entering or leaving it.
What is happening technically?
Basınç kompanzasyonsuz bir kısıcıda debi, basınç farkıyla değişir. Kısma kaybı Δp × Q / 600 kW olarak ısıya dönüşür.
In practice
If speed changes with load, examine the restrictor type and pressure differential together.
● Pressure / supply● Return┄ Pilot (illustrative)
Educational diagram only; not a manufacturing or safety circuit. The pilot line illustrates the line style only.
Symptom → check → solution
If movement, pressure or temperature changes, first identify the conditions in which the symptom occurs. Record existing gauge readings. Base maintenance or circuit examination on causes confirmed by measurements.
Select your symptom in Fault Hunter →Quick check
Which is the correct approach before replacing a component?
TECHNICAL SUPPORT ↗